Please use this identifier to cite or link to this item:
http://dspace.aiub.edu:8080/jspui/handle/123456789/1084
Title: | Augmentation of Battery Management Systems in Smart-Grid operation using Fuzzy Logic |
Authors: | Sabiqun, Nahar Md. Redowan Mahmud, Arnob Shatil, Abu Hena MD |
Keywords: | Fuzzy Logic Controller , Rule base , Battery management systems , Smart-grid , Super-capacitor batteries |
Issue Date: | 1-Feb-2021 |
Publisher: | IEEE |
Citation: | S. Nahar, M. R. M. Arnob and A. H. M. Shatil, "Augmentation of Battery Management Systems in Smart-Grid operation using Fuzzy Logic," 2021 2nd International Conference on Robotics, Electrical and Signal Processing Techniques (ICREST), DHAKA, Bangladesh, 2021, pp. 85-89, doi: 10.1109/ICREST51555.2021.9331034. |
Abstract: | This paper proposes an idea of optimizing battery management system using fuzzy logic for a smart grid system. The involvement of a fuzzy logic controller makes the existing control mechanisms for the battery management system more intelligent hence allowing the system to prioritize between the loads and multiple batteries in the battery storage system (BSS) which enables the utilization of the harnessed solar energy with greater service continuity. This design involves a much more effective algorithm of a load and battery management system using fuzzy sets which allows to optimize solar power utilization and maintaining smooth battery health conditions. Finally, a comparative study is illustrated showing the differences between a system working with a greater number of membership functions (64 rules) and the one working with only two membership functions (8 rules). |
URI: | http://dspace.aiub.edu:8080/jspui/handle/123456789/1084 |
Appears in Collections: | Publications From Faculty of Engineering |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.