Please use this identifier to cite or link to this item: http://dspace.aiub.edu:8080/jspui/handle/123456789/1117
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAlim, Nusrat-
dc.contributor.authorUddin, Mohammad Nasir-
dc.date.accessioned2023-09-20T07:45:11Z-
dc.date.available2023-09-20T07:45:11Z-
dc.date.issued2018-03-31-
dc.identifier.citationNusrat Alim, Mohammad Nasir Uddin, “Surface Plasmon Resonance Biosensor in Healthcare Application Using Kretschsmann & Otto Configuration,” AIUB Journal of Science and Engineering (AJSE), vol. 17, no. 1, pp. 1-6, 31st Mar. 2018, doi: https://doi.org/10.53799/ajse.v17i1.1 (Scopus Indexed Q-4, IF 0.333)en_US
dc.identifier.issnp-ISSN 1608-3679, e-ISSN 2520-4890-
dc.identifier.urihttp://dspace.aiub.edu:8080/jspui/handle/123456789/1117-
dc.description.abstractIn this study, a planar D-shape optical fiber sensor based on Surface Plasmon Resonance phenomenon using two different excitation methods has been demonstrated. The proposed bio-sensor uses Amplitude-Wavelength hybrid detection technique to determine the change in urine refractive index that depends on resonance parameters. The analysis employs finite element method to investigate the optical properties of the proposed sensor. From the results it can be evident that Otto configuration offers greater amount of reflected light intensity dip for a particular urine refractive index in comparison with Kretschmann configuration. For an example, for Otto configuration the dip of reflected light intensity measured in terms of reflectance which attains a value 0.5 for ns (urine refractive index) of 1.489 while Kretschmann configuration provides a dip of 0.65 for the same value of ns. Results also show that the sharpness of reflectance is comparatively higher for the sensor using Otto configuration in comparison with Kretschmann configuration in case of wavelength interrogation. Thus, Otto configuration offers better performance in comparison with Kretschmann configuration.en_US
dc.language.isoen_USen_US
dc.publisherORP-AIUBen_US
dc.relation.ispartofseriesvol.17;Issue 1-
dc.subjectSurface Plasmon Resonanceen_US
dc.subjectBiosensoren_US
dc.titleSurface Plasmon Resonance Biosensor in Healthcare Application Using Kretschsmann & Otto Configurationen_US
dc.typeArticleen_US
Appears in Collections:Publications From Faculty of Engineering

Files in This Item:
File Description SizeFormat 
J9_Dr_Nasir_DSpace_Publication_Info_Upload_FE.docx3.86 MBMicrosoft Word XMLView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.