Please use this identifier to cite or link to this item: http://dspace.aiub.edu:8080/jspui/handle/123456789/2013
Full metadata record
DC FieldValueLanguage
dc.contributor.authorHazari, Md. Rifat-
dc.contributor.authorMannan, Mohammad Abdul-
dc.contributor.authorUmemura, Atsushi-
dc.contributor.authorTakahashi, Rion-
dc.contributor.authorTamura, Junji-
dc.date.accessioned2024-01-16T10:21:26Z-
dc.date.available2024-01-16T10:21:26Z-
dc.date.issued2018-11-
dc.identifier.citationMd. Rifat Hazari, Mohammad Abdul Mannan, Atsushi Umemura, Rion Takahashi, Junji Tamura, “Stabilization of Wind Farm by Using PMSG Based Wind Generator Taking Grid Codes into Consideration,” Journal of Power and Energy Engineering, Vol. 6, pp. 40-52, 2018.en_US
dc.identifier.issn2327-5901-
dc.identifier.urihttp://dspace.aiub.edu:8080/jspui/handle/123456789/2013-
dc.description.abstractThis paper presents a new operational strategy for a large-scale wind farm (WF) which is composed of both fixed speed wind turbines with squirrel cage induction generators (FSWT-SCIGs) and variable speed wind turbines with permanent magnet synchronous generators (VSWT-PMSGs). FSWT-SCIGs suffer greatly from meeting the requirements of fault ride through (FRT), because they are largely dependent on reactive power. Integration of flexible ac transmission system (FACTS) devices is a solution to overcome that problem, though it definitely increases the overall cost. Therefore, in this paper, a new method is proposed to stabilize FSWT-SCIGs by using VSWT-PMSGs in a WF. This is achieved by injecting the reactive power to the grid during fault condition by controlling the grid side converter (GSC) of PMSG. The conventional proportional-integral (PI)-based cascaded controller is usually used for GSC which can inject small amount of reactive power during fault period. Thus, it cannot stabilize larger rating of SCIG. In this paper, a suitable fuzzy logic controller (FLC) is proposed in the cascaded controller of GSC of PMSG in order to increase reactive power injection and thus improve the FRT capability of WF during voltage dip situation due to severe network fault. To evaluate the proposed controller performance, simulation analyses are performed on a modified IEEE nine-bus system. Simulation results clearly show that the proposed method can be a cost-effective solution which can effectively stabilize the larger rating of SCIG compared to conventional PI based control strategy.en_US
dc.language.isoenen_US
dc.publisherScientific Researchen_US
dc.subjectWind Turbine Generatoren_US
dc.subjectFuzzy Logic Controlleren_US
dc.subjectPower System Stabilityen_US
dc.subjectPower Converteren_US
dc.subjectPI Controlleren_US
dc.titleStabilization of Wind Farm by Using PMSG Based Wind Generator Taking Grid Codes into Considerationen_US
dc.typeArticleen_US
Appears in Collections:Publications From Faculty of Engineering

Files in This Item:
File Description SizeFormat 
65J_Dr Rifat_2018_JPEE_14.pdf126.57 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.