Please use this identifier to cite or link to this item:
http://dspace.aiub.edu:8080/jspui/handle/123456789/855
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Muyeen, S. M | - |
dc.contributor.author | Mannan, Mohammad Abdul | - |
dc.contributor.author | Hasan Ali, Mohd. | - |
dc.contributor.author | Rion, Takahashi | - |
dc.contributor.author | Murata, Toshiaki | - |
dc.contributor.author | Tamura, Junji | - |
dc.date.accessioned | 2023-01-25T09:35:25Z | - |
dc.date.available | 2023-01-25T09:35:25Z | - |
dc.date.issued | 2006-12 | - |
dc.identifier.citation | S. M. Muyeen, Mohammad Abdul Mannan, Mohd. Hasan Ali, Rion Takahashi, Toshiaki Murata, and Junji Tamura, “Stabilization of Wind Turbine Generator System by STATCOM”, IEEJ Transactions on Electrical and Electronic Engineering, Vol. 126, No. 10, pp. 1073-1082, Dec., 2006. | en_US |
dc.identifier.issn | 1931-4981 | - |
dc.identifier.uri | http://dspace.aiub.edu:8080/jspui/handle/123456789/855 | - |
dc.description.abstract | Recently voltage-source or current-source inverter based various FACTS devices have been used for flexible power flow control, secure loading, damping of power system oscillation and even for the stabilization of wind energy generation. In this paper, we propose the static synchronous compensator (STATCOM) based on voltage source converter (VSC) PWM technique to stabilize grid connected wind generator system. A simple control strategy of STATCOM is adopted where only measurement of rms voltage at the wind generator terminal is needed. Fuzzy logic controller rather than conventional PI controller is proposed as the control methodology of STATCOM. Multi-mass shaft model of wind turbine generator system (WTGS) is also considered as shaft modeling has a big influence on the transient performance of WTGS. Transient performance of STATCOM connected WTGS is compared also with that of pitch controlled WTGS. Both symmetrical and unsymmetrical faults are analyzed. Moreover, the steady state performance of STATCOM connected WTGS is analyzed. It is reported that STATCOM can reduce the voltage fluctuation significantly. Finally STATCOM is applied to a wind park model with multiple wind generators. Comprehensive results are presented to assess the performance of STATCOM connected WTGS, where the simulations have been done by PSCAD/EMTDC. | en_US |
dc.description.sponsorship | Author affiliation is American International University-Bangladesh [AUB] | en_US |
dc.language.iso | en | en_US |
dc.publisher | Institute of Electrical Engineers of Japan | en_US |
dc.subject | Fuzzy Logic Controller | en_US |
dc.subject | Multi-mass Shaft Model | en_US |
dc.subject | PWM Voltage Source Converter | en_US |
dc.subject | Pitch Controller | en_US |
dc.subject | STATCOM | en_US |
dc.subject | Wind Generator | en_US |
dc.title | Stabilization of Wind Turbine Generator System by STATCOM | en_US |
dc.type | Article | en_US |
Appears in Collections: | Publications From Faculty of Engineering |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
07J_DMAM_EEE_FE_AIUB.pdf | 183.01 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.